The VenoSense System

A modular platform transforming DVT detection

VenoSense reimagines traditional ultrasound workflows through a modular platform that works with your existing equipment. Our system consists of three key components working together: a universal clamp system, an automated probe positioning system, and an edge computing AI module.

By automating the scanning process and applying real-time AI analysis, VenoSense standardizes deep vein thrombosis detection while reducing the expertise required. This enables consistent, high-quality DVT screening in more clinical settings without the need for specialized sonographers.

UC
Universal Clamp
AS
Automation System
AI
Edge AI Module
01

Compatible with Existing Equipment

Our universal clamp works with standard Doppler ultrasound probes, maximizing your current investment.

02

Automated Scanning Process

Precision-controlled movement ensures consistent ultrasound imaging without operator variability.

03

On-Device AI Analysis

Secure, local processing with no cloud dependency for instant results and patient data privacy.

Key Components

How the VenoSense platform works together

01

Universal Clamp System

Our adaptable clamp secures to virtually any standard ultrasound probe, transforming it into an automated scanning device without modifying your existing equipment.

Compatible with linear array probes from major manufacturers
Adjustable grip system for secure fit on various probe sizes
Quick-release mechanism for rapid attachment/detachment
Non-obstructive design preserves full probe functionality
Medical-grade materials for durability and easy sterilization
02

Automated Probe Positioning

Our precision motor system guides the ultrasound probe across the patient's leg in a standardized pattern, ensuring comprehensive venous examination without operator variability.

Precision-controlled movement with 0.1mm positioning accuracy
Adjustable pressure system maintains optimal probe contact
Multi-axis movement for complete anatomical coverage
Silent operation for improved patient experience
Patient-specific scan protocols adapt to different anatomies
03

Edge Computing AI Module

Our edge computing module connects to your ultrasound system and uses advanced AI to analyze ultrasound imagery in real-time, all while keeping patient data secure and on-site.

Secure, on-device processing with no cloud dependency
Neural networks trained on 50,000+ clinical DVT images
Real-time analysis of vessel compressibility and blood flow
Automated Wells score calculation and risk stratification
Tablet interface for results review and clinician interaction

Intuitive Clinical Interface

Designed for clarity and clinical decision support

01

Tablet Companion Display

Secure tablet mount attaches to your existing ultrasound monitor, providing an intuitive interface for scan control and results review.

02

Guided Workflow

Step-by-step interface guides clinicians through patient assessment, scan preparation, and results interpretation.

03

Actionable Results

Clear visualization of findings with color-coded risk assessment and recommended next steps based on clinical guidelines.

04

Integration Options

Export findings to DICOM/PACS systems and electronic health records through HL7/FHIR standards.

Patient Assessment

Technical Specifications

The numbers behind VenoSense's capabilities

Universal Clamp

  • Compatibility: Most linear ultrasound probes
  • Materials: Medical-grade polymer blend
  • Attachment Method: Quick-release locking mechanism
  • Probe Width Range: 30-80mm
  • Weight: 120g

Automation System

  • Movement Precision: 0.1mm
  • Scan Area: Up to 30cm path length
  • Pressure Control: Variable 1-5 newtons
  • Motor Type: Brushless DC with encoder
  • Battery Life: 6+ hours operation

Edge Computing

  • Processor: Edge TPU / Neural Engine
  • Memory: 8GB LPDDR4X
  • Storage: 128GB NVMe
  • Analysis Time: <30 seconds
  • Video Inputs: HDMI, SDI, USB

Clinical Performance

  • Sensitivity: 95.7%*
  • Specificity: 94.2%*
  • Scan Time: 5-8 minutes per leg
  • Setup Time: ~2 minutes
  • Safety: IEC 60601 Compliant

* Based on pre clinical validation studies

Experience VenoSense Technology

Ready to see how VenoSense can transform DVT detection in your clinical setting?